No hot water but the heating works: causes by installation type (2027)

Short answer: If the radiators heat but the tap stays cold, the fault is almost always on the hot-water side: on a combi boiler usually the diverter valve, flow sensor or a scaled plate heat exchanger; on a separate cylinder the thermostat, sensor or element. Check the error code, the pressure gauge (1–1.5 bar when cold) and the other taps, then call a technician before anything is opened.

Prices in this article are indicative Belgian market ranges, not Alpha Services Benelux's price list. Your fixed price is in the quote.

Which system do you have? Causes differ

First identify your installation, because the likely causes differ. A boiler that heats the radiators and also supplies hot tap water is a combi boiler; a separate storage tank (called a 'boiler' or 'ballon' in Belgium) points to a boiler with a hot-water cylinder or an electric water heater.

Typical causes when the heating works but there is no hot water
InstallationLikely causesWho handles it
Combi boiler (gas)Stuck diverter valve, flow sensor, scaled plate heat exchanger, low water pressureQualified heating engineer
Boiler with separate cylinderCylinder thermostat or sensor, three-way valve, scale in the cylinder's heat exchangerHeating engineer or plumber
Electric water heaterHeating element, safety thermostat, tripped fuse or RCD after a power cutElectrician or plumber
All typesLow pressure on hot water only: scale in a tap filter, a valve, the pressure reducerPlumber

The rating plate on the appliance tells you the model. Note the brand, type and any error code before calling: it speeds up the diagnosis.

Combi boiler: diverter valve, flow sensor and plate heat exchanger

On a combi boiler one appliance produces both heating and hot water. If radiators warm up but the tap stays cold, the fault is usually in the part that switches to hot water or heats it.

All four mean opening the appliance or descaling the water circuit. That is work for a qualified technician, not for DIY.

Boiler with a separate hot-water cylinder

With a cylinder, water is heated in a tank. If it stays lukewarm while the heating works, the cause is more often the cylinder's controls than the boiler itself.

Looking at the settings on the display is fine; opening the appliance or replacing parts is not for homeowners.

Electric water heater: element, safety thermostat and power cuts

With an electric water heater, hot water is independent of the boiler, so the heating can work perfectly while the heater does nothing.

An electric water heater is live and under pressure. Do not open covers or touch wiring. Our guide to a breaker or RCD that keeps tripping explains the sensible checks.

Low pressure on the hot water only

Weak hot water while cold water runs normally points to a local cause; weak water everywhere points to the supply. You can tell the difference without opening anything.

Do not confuse this with the heating circuit pressure shown on the boiler's gauge. According to Vaillant Belgium it is normally 1 to 1.5 bar cold and rises to about 2 bar when warm; below 1 bar is too low and above 3 bar is too high.

What you can safely check yourself

Five things can be observed without opening anything: error code, pressure gauge, other taps, settings, and whether the problem started after a power cut or clock change.

Observing without opening: what it can mean
What you seePossible meaningAction
Error code on the displaySensor, pressure or ignition faultNote the code and model, call a technician
Gauge below 1 barHeating circuit pressure too lowIf it keeps dropping: possible leak, have it checked
Only one tap coldProblem with that tapPlumber, not a boiler fault
All taps only lukewarmScale, sensor or valveHave a technician inspect it
Right after a power cut or clock changeSettings or protection trippedCheck clock and mode on the display; if it repeats, call

Vaillant Belgium advises fully opening a hot tap for a few seconds to see whether the boiler reacts. If that changes nothing, your own investigation stops here.

Dangerous or urgent: when to call right away

Call a technician right away if you see soot, the boiler locks out with a safety code, or water is leaking.

If you smell gas: indoors, don't use switches, flames or your phone, open windows and doors, leave the home and, from a place where you no longer smell gas, call the grid operator (Fluvius, Sibelga, ORES) or 112 in an emergency such as fire or an explosion. This is not a hot-water fault: get to safety first, then call.

Carbon monoxide (CO) is the main hazard with gas boilers and gas water heaters. According to the Flemish government, signs of CO include headache, nausea or dizziness in several people at once, soot, and a yellow rather than blue flame. Test-Aankoop warns that flame colour and soot are not reliable indicators and reports roughly 30 CO deaths a year in Belgium. If in doubt: ventilate, leave the building, stop using the appliance and call 112. CO detectors should meet NBN EN 50291.

No hot water without such signs is not an immediate danger, but do not wait too long: a technician must find the cause. Heating pans on the hob or using an electric heater is only a stopgap; see what to check when the boiler stops. Heating and hot-water failures are handled 24/7 through our boiler and heating page (0485 44 55 12).

Repair or replace: how to decide

A single part such as a valve or sensor is usually repairable; replacement comes into play if the appliance is old, fails repeatedly or the cylinder has corroded through. Ask the technician to explain both scenarios in writing.

If you end up choosing a new appliance, market prices are in our central-heating boiler replacement cost guide.

Fixed quote after a site visit

Alpha Services Benelux does the work with its own team, active since 2014. VAT BE 0541.320.178.

Request a quote

0485 44 55 12 · WhatsApp

Frequently asked questions

Why do I have no hot water but the heating works?

On a combi boiler it is often a stuck diverter valve, a flow sensor or a scaled plate heat exchanger. With a separate cylinder, the thermostat, sensor or element are common culprits. A technician identifies the faulty part.

What is the normal boiler pressure?

According to Vaillant Belgium, 1 to 1.5 bar cold and about 2 bar when warm. Below 1 bar is too low, above 3 bar too high. If it keeps dropping, have the installation checked.

No hot water after a power cut: what could it be?

With an electric water heater, a fuse, RCD or the timer may have tripped or shifted. With a gas boiler, the appliance may have locked out or the clock shifted. If it persists, call an electrician or heating engineer.

Can I replace the diverter valve myself?

No, leave it to a qualified technician. These are parts of a pressurised gas appliance, with leak and CO risks, and non-compliant work can affect the manufacturer's warranty.

When should I call a technician?

Immediately for soot, a leak or a recurring error code. Also call if hot water is missing for more than a day and you find no simple cause. If you smell gas, don't call a technician first: leave the home and alert the grid operator or 112.

Sources

  1. Werkt het warm water niet? Zo lost u het op! — Vaillant België
  2. Drukdalingen en lage druk in gasboilers opgelost — Vaillant België
  3. Mijn ketel levert warm water maar geen verwarming — Vaillant België
  4. Let op voor CO-vergiftiging — Vlaamse overheid
  5. CO in je huis detecteren en voorkomen — Test-Aankoop
  6. Gasgeur of gaslek? Veiligheidsvoorschriften bij gasgeur — Fluvius
  7. My boiler is working but I have no hot water — Viessmann UK