No hot water but the heating works: causes by installation type (2027)
Short answer: If the radiators heat but the tap stays cold, the fault is almost always on the hot-water side: on a combi boiler usually the diverter valve, flow sensor or a scaled plate heat exchanger; on a separate cylinder the thermostat, sensor or element. Check the error code, the pressure gauge (1–1.5 bar when cold) and the other taps, then call a technician before anything is opened.
Prices in this article are indicative Belgian market ranges, not Alpha Services Benelux's price list. Your fixed price is in the quote.
Which system do you have? Causes differ
First identify your installation, because the likely causes differ. A boiler that heats the radiators and also supplies hot tap water is a combi boiler; a separate storage tank (called a 'boiler' or 'ballon' in Belgium) points to a boiler with a hot-water cylinder or an electric water heater.
| Installation | Likely causes | Who handles it |
|---|---|---|
| Combi boiler (gas) | Stuck diverter valve, flow sensor, scaled plate heat exchanger, low water pressure | Qualified heating engineer |
| Boiler with separate cylinder | Cylinder thermostat or sensor, three-way valve, scale in the cylinder's heat exchanger | Heating engineer or plumber |
| Electric water heater | Heating element, safety thermostat, tripped fuse or RCD after a power cut | Electrician or plumber |
| All types | Low pressure on hot water only: scale in a tap filter, a valve, the pressure reducer | Plumber |
The rating plate on the appliance tells you the model. Note the brand, type and any error code before calling: it speeds up the diagnosis.
Combi boiler: diverter valve, flow sensor and plate heat exchanger
On a combi boiler one appliance produces both heating and hot water. If radiators warm up but the tap stays cold, the fault is usually in the part that switches to hot water or heats it.
- Diverter (three-way) valve: sends boiler water either to the radiators or to the hot-water side. Stuck on heating, it gives warm radiators and no hot water. Vaillant Belgium lists this as a cause and leaves the repair to a professional.
- Flow sensor: detects that a tap is open and triggers the burner. A faulty or dirty sensor keeps the appliance in heating mode.
- Scaled plate heat exchanger: scale restricts heat transfer, so water stays lukewarm or cools quickly, especially in hard-water areas.
- Low system pressure: if the pressure drops too far the boiler shuts down to protect the system, usually the whole appliance. If the heating works, this is a less likely cause.
All four mean opening the appliance or descaling the water circuit. That is work for a qualified technician, not for DIY.
Boiler with a separate hot-water cylinder
With a cylinder, water is heated in a tank. If it stays lukewarm while the heating works, the cause is more often the cylinder's controls than the boiler itself.
- Cylinder thermostat or sanitary sensor: measures the water temperature and calls for heat. A wrong reading means no heat demand.
- Three-way valve or charging pump: without circulation, heat never reaches the cylinder.
- Scale in the cylinder's heat exchanger: according to Vaillant Belgium, a known reason for lukewarm water with warm radiators.
- Settings: a shifted clock, holiday or standby mode can switch off hot-water production. Vaillant recommends a hot-water setpoint of 50–55 °C to limit legionella risk.
Looking at the settings on the display is fine; opening the appliance or replacing parts is not for homeowners.
Electric water heater: element, safety thermostat and power cuts
With an electric water heater, hot water is independent of the boiler, so the heating can work perfectly while the heater does nothing.
- Heating element: wears or scales up over the years and can burn out. The water then stays cold or barely warm.
- Safety thermostat: protects against overheating and can trip. Resetting it belongs to a professional: if it tripped, there is a reason.
- After a power cut: a fuse or RCD on the heater circuit may have tripped, or the timer (night tariff) is out of sync. If the RCD trips again, have an electrician look at it.
An electric water heater is live and under pressure. Do not open covers or touch wiring. Our guide to a breaker or RCD that keeps tripping explains the sensible checks.
Low pressure on the hot water only
Weak hot water while cold water runs normally points to a local cause; weak water everywhere points to the supply. You can tell the difference without opening anything.
- Only one tap is weak: often scale in that tap's aerator or filter.
- Hot water weak everywhere but cold normal: a valve, a non-return valve or scale in the cylinder circuit may be to blame.
- Cold water weak too: the supply pipe or pressure reducer is the issue; contact the water company or a plumber.
Do not confuse this with the heating circuit pressure shown on the boiler's gauge. According to Vaillant Belgium it is normally 1 to 1.5 bar cold and rises to about 2 bar when warm; below 1 bar is too low and above 3 bar is too high.
What you can safely check yourself
Five things can be observed without opening anything: error code, pressure gauge, other taps, settings, and whether the problem started after a power cut or clock change.
| What you see | Possible meaning | Action |
|---|---|---|
| Error code on the display | Sensor, pressure or ignition fault | Note the code and model, call a technician |
| Gauge below 1 bar | Heating circuit pressure too low | If it keeps dropping: possible leak, have it checked |
| Only one tap cold | Problem with that tap | Plumber, not a boiler fault |
| All taps only lukewarm | Scale, sensor or valve | Have a technician inspect it |
| Right after a power cut or clock change | Settings or protection tripped | Check clock and mode on the display; if it repeats, call |
Vaillant Belgium advises fully opening a hot tap for a few seconds to see whether the boiler reacts. If that changes nothing, your own investigation stops here.
Dangerous or urgent: when to call right away
Call a technician right away if you see soot, the boiler locks out with a safety code, or water is leaking.
If you smell gas: indoors, don't use switches, flames or your phone, open windows and doors, leave the home and, from a place where you no longer smell gas, call the grid operator (Fluvius, Sibelga, ORES) or 112 in an emergency such as fire or an explosion. This is not a hot-water fault: get to safety first, then call.
Carbon monoxide (CO) is the main hazard with gas boilers and gas water heaters. According to the Flemish government, signs of CO include headache, nausea or dizziness in several people at once, soot, and a yellow rather than blue flame. Test-Aankoop warns that flame colour and soot are not reliable indicators and reports roughly 30 CO deaths a year in Belgium. If in doubt: ventilate, leave the building, stop using the appliance and call 112. CO detectors should meet NBN EN 50291.
No hot water without such signs is not an immediate danger, but do not wait too long: a technician must find the cause. Heating pans on the hob or using an electric heater is only a stopgap; see what to check when the boiler stops. Heating and hot-water failures are handled 24/7 through our boiler and heating page (0485 44 55 12).
Repair or replace: how to decide
A single part such as a valve or sensor is usually repairable; replacement comes into play if the appliance is old, fails repeatedly or the cylinder has corroded through. Ask the technician to explain both scenarios in writing.
- Ask which part exactly is faulty and whether it is the cause, not just the symptom.
- Ask what else could fail and how old the appliance is.
- A fixed written quote after a site visit helps avoid surprises.
If you end up choosing a new appliance, market prices are in our central-heating boiler replacement cost guide.
Fixed quote after a site visit
Alpha Services Benelux does the work with its own team, active since 2014. VAT BE 0541.320.178.
Request a quoteFrequently asked questions
Why do I have no hot water but the heating works?
On a combi boiler it is often a stuck diverter valve, a flow sensor or a scaled plate heat exchanger. With a separate cylinder, the thermostat, sensor or element are common culprits. A technician identifies the faulty part.
What is the normal boiler pressure?
According to Vaillant Belgium, 1 to 1.5 bar cold and about 2 bar when warm. Below 1 bar is too low, above 3 bar too high. If it keeps dropping, have the installation checked.
No hot water after a power cut: what could it be?
With an electric water heater, a fuse, RCD or the timer may have tripped or shifted. With a gas boiler, the appliance may have locked out or the clock shifted. If it persists, call an electrician or heating engineer.
Can I replace the diverter valve myself?
No, leave it to a qualified technician. These are parts of a pressurised gas appliance, with leak and CO risks, and non-compliant work can affect the manufacturer's warranty.
When should I call a technician?
Immediately for soot, a leak or a recurring error code. Also call if hot water is missing for more than a day and you find no simple cause. If you smell gas, don't call a technician first: leave the home and alert the grid operator or 112.
Sources
- Werkt het warm water niet? Zo lost u het op! — Vaillant België
- Drukdalingen en lage druk in gasboilers opgelost — Vaillant België
- Mijn ketel levert warm water maar geen verwarming — Vaillant België
- Let op voor CO-vergiftiging — Vlaamse overheid
- CO in je huis detecteren en voorkomen — Test-Aankoop
- Gasgeur of gaslek? Veiligheidsvoorschriften bij gasgeur — Fluvius
- My boiler is working but I have no hot water — Viessmann UK