Breaker or RCD keeps tripping in a Belgian home: what to check and when to call

Short answer: A circuit breaker trips on overload or short circuit; a 30 mA RCD (earth-leakage switch) trips on leakage to earth, for example from a faulty appliance or moisture. Note which switch fell, what was on, and whether it trips with everything unplugged. Call a professional now for a burning smell, heat or scorch marks at sockets or the panel, a trip straight after reset, or water near electrics.

Prices in this article are indicative Belgian market ranges, not Alpha Services Benelux's price list. Your fixed price is in the quote.

Which switch tripped: breaker or RCD?

A circuit breaker protects the wiring of one circuit against overload and short circuit. A differential device (RCD, earth-leakage switch) protects people by tripping when current leaks to earth. Knowing which one fell already narrows the cause.

Circuit breaker versus RCD: what each one reacts to
DeviceProtects againstTypical cause when it trips
Circuit breaker (one per circuit)Overload, short circuitToo many appliances on one circuit, a heater or kettle running at full load, a short circuit in a cable or appliance
30 mA RCDLeakage to earth (shock risk)Faulty appliance, moisture in a socket, light or outdoor cable, several appliances each leaking a little
300 mA RCD at the head of the installationLarger earth leakage on the whole installationA fault on a circuit not covered by a 30 mA device, or a general insulation problem

Read the label next to the switch (kitchen, bathroom, lighting). If the whole house is dark, look at the large switch at the head of the panel as well.

What can I safely check when my breaker keeps tripping?

You can make a few observations without tools and without opening any cover. Write them down, because they are exactly what a technician will ask.

  1. Which switch tripped (breaker or RCD) and what its label says.
  2. What was switched on at that moment (oven, washing machine, heater, kettle).
  3. Does it trip again if you unplug everything on that circuit and reset once?
  4. Does it happen mainly after rain, in humid weather, or when an outdoor light or garden socket is used?
  5. Is there any smell, warmth, buzzing or discolouration at the panel or at a socket?
Safe checks versus what you should never do
Safe checks (no tools)Never do
Look at which switch is down and read its labelOpen the panel cover or touch wires
Unplug appliances on the circuit with dry handsReset again and again if it trips immediately
Reset once, then note whether it holdsFit a higher-rated breaker or tape the switch up
Note timing: rain, humidity, a specific applianceTouch sockets or appliances while standing in water
Smell and look at sockets from a distanceKeep using a socket that is warm, brown or smells burnt

The reason for the ban on a higher-rated breaker: in the AREI, the maximum breaker rating depends on the cable cross-section. The table in the Royal Decree published in the Belgisch Staatsblad (28 March 2023) allows a maximum of 16 A for 1.5 mm² and 20 A for 2.5 mm². Only a professional can see what is behind the wall.

Symptom table: can it wait or call now?

If the switch holds after one reset and nothing smells or feels hot, you can usually book a technician for the coming days. If it trips straight away or you notice heat, treat it as urgent.

Symptoms, likely causes and urgency
SymptomLikely causeCan wait or call now?
Breaker trips when oven and kettle run together, holds after unpluggingOverload of one circuitCan wait: spread the load and book a check
RCD trips only after rain or on humid daysMoisture in an outdoor socket, light or cableBook soon; stop using the outdoor equipment
RCD trips when one specific appliance is plugged inFaulty appliance leaking to earthLeave it unplugged; have it checked or replaced
RCD or breaker trips again immediately on reset, with everything unpluggedFault in the wiring, a socket or the device itselfCall now
Burning smell, heat, scorch marks or crackling at a socket or the panelOverheating connection or insulation damageCall now; call 112 if there is smoke or flame
Water near sockets, panel or meterMoisture in live partsCall now; do not touch anything wet

When is it urgent?

It is urgent when there are signs of heat or fire risk, when the device trips at once on reset, or when water reaches electrical parts.

Alpha Services Benelux offers emergency service 24/7 for electrical, plumbing and heating emergencies. See our electrician page.

Network outage or fault in my house?

If neighbours also have no power, the cause is probably on the network; if their lights are on, the problem is probably in your installation.

Fluvius (Flanders) asks first whether the light is still on at the neighbours and shows an outage overview on its site. Sibelga (Brussels) publishes actual power outages online, and ORES (Wallonia) says the problem may come from your home if neighbours still have power or street lights are on; it also has a live outage map. The emergency numbers are listed on the operators' websites. The network operator handles the street network, not a breaker tripping inside your house. See also our power-cut checklist.

What do the AREI/RGIE rules require?

The AREI (RGIE) requires earth-leakage protection in layers: at least one differential device at the head of the installation with a tripping current of at most 300 mA (Royal Decree of 2023, Belgisch Staatsblad).

According to Volta, the Belgian electrotechnical knowledge centre, socket circuits not intended for fixed appliances must be behind 30 mA differential devices where earth resistance is 30 ohm or less. Bathroom, washing machine, dryer and dishwasher circuits are also protected at 30 mA or less. For installations started after 1 June 2023, at most 8 end circuits may sit behind one 30 mA device; older installations may have more. This is why one leaking appliance can take out several rooms. Volta also notes that some RCD test buttons cannot work in a 3x230 V network and that test frequency follows the manufacturer's instructions. If your installation is old or was never inspected, read our guide on the AREI inspection and questions for your electrician.

What to tell the technician on the phone

A clear description saves a wasted visit. Have these points ready:

Prices for panel work vary widely; see our fuse box replacement cost guide for market ranges. Ranges in our guides come from 2025-2026 market sources and are an orientation for 2027.

Fixed quote after a site visit

Alpha Services Benelux does the work with its own team, active since 2014. VAT BE 0541.320.178.

Request a quote

0485 44 55 12 · WhatsApp

Frequently asked questions

Why does my breaker keep tripping?

A breaker trips on overload or short circuit: too many appliances on one circuit, or a damaged cable or appliance. Unplug everything on that circuit and reset once. If it holds, plug appliances back in one at a time; if it trips straight away, call an electrician.

Why does my RCD keep tripping after rain?

An RCD trips on leakage to earth, and moisture in an outdoor socket, light or cable is a common cause. Stop using outdoor equipment and note when it happens. Because the fault is in the wiring, have a professional check it.

Is it dangerous to reset the RCD repeatedly?

Reset once to see whether it holds. If it trips again at once, the RCD is doing its job by cutting a fault, so repeated resets are not advised. Leave it off and call a professional.

How do I know if it is a power cut or my installation?

Check whether neighbours and street lights have power. If yes, the fault is probably yours. If no, check the operator outage map (Fluvius, Sibelga, ORES) and contact the operator through its website.

Does the RGIE require a 30 mA RCD?

Yes for most socket circuits and wet-room circuits, according to Volta's summary of the AREI. The head of the installation needs a differential device of at most 300 mA. The details depend on when your installation was built and on earth resistance.